From: Raul Hennings-Yeomans (raul@casino.PHYS.CWRU.Edu)
Date: Thu Mar 01 2007 - 00:11:47 CET
Dear fluka experts
I have 38 scintillator panels in my simulation and would like to
dump energy deposited in the scintillator panels per primary, ie
in an event by event way. Would like to take into account energy
deposited by charged particles (~2MeV energy deposition per cm for
minimum ionizing particles) and hydrogen recoils with quenching
taken in to account. I looked at the manual, EVENTBIN doesnt allow
me to do a per region dump, so I looked into mgdraw.f and it looks
like I could get energy deposition per region per event by summing
each energy deposition that occured in the a region within the event
in ENDRAW, and then dumping it the sum in EEDRAW.
I am not getting the ~10MeV peak for a 5cm thick scintillator panel.
Could you give me some orientation on how to dump the energy deposition
in a per region per event way? i attach my mgdraw.f
Thanks in advanced
Raul
This archive was generated by hypermail 2.1.6 : Thu Mar 01 2007 - 12:08:53 CET