Re: [fluka-discuss]: Bremsstrahlung Dose Isolation

From: Luigi Salvatore Esposito <luigi.salvatore.esposito_at_cern.ch>
Date: Sat, 27 May 2017 08:06:51 +0000

Dear Dirk,
Without giving a look at your routines, one can only make guesses…
1. Have you included the USERDUMP in the input file with the correct settings? it seems yes…
2. Is the common (TRACKR) include in both mgdraw and comscw routines? By default, it is

Best regards, luigi

On 26.05.17, 18:30, "owner-fluka-discuss_at_mi.infn.it on behalf of Bartkoski,Dirk Alan" <owner-fluka-discuss_at_mi.infn.it on behalf of DABartkoski_at_mdanderson.org> wrote:

    Based on your suggestions and information in the FLUKA advanced course I made an attempt to use latching to separate the Bremsstrahlung dose by flagging all particles created in a bremsstrahlung event and using that flag for scoring by adding
    
    To the mgdraw.f, USRDRAW entry:
    IF ( ICODE .EQ. 208) THEN
            ISPUSR(1) = 1
    END IF
    
    To comscw.f:
    
    COMSCW = ZEROZERO
    
    IF (ISPUSR(1) .EQ. 1) THEN
            COMSCW = ONEONE
    END IF
    
    After testing, I know that USRDRAW is flagging ISPUSR(1) when there is a bremsstrahlung event but when comscw.f runs, it shows ISPUSR(1) = 0. It is like the values I set with mgdraw.f are not being propagated. From my understanding, propagation of ISPUSR values should happen by default but I added the default stupre.f routine to be sure and ISPUSR values are still not propagating. All my user files compile without error and the simulation runs fine. Am I missing something that allows the ISPUSR values to be propagated?
    _______________________________________________________________________________
    Dirk A. Bartkoski, Ph.D.
    Research Scientist | Division of Radiation Oncology
    
    T. Boone Pickens Tower (FCT8.5007)
    1515 Holcombe Blvd.
    Unit 1420
    Houston, TX 77030
    (713)794-5026
    
    -----Original Message-----
    From: me_at_marychin.org [mailto:me_at_marychin.org]
    Sent: Monday, April 03, 2017 7:45 PM
    To: Bartkoski,Dirk Alan <DABartkoski_at_mdanderson.org>
    Cc: fluka-discuss_at_fluka.org; owner-fluka-discuss_at_mi.infn.it
    Subject: Re: [fluka-discuss]: Bremsstrahlung Dose Isolation
    
    This is in the FLUKA advanced courses, under 'user routines'.
    
    On 2017-04-03 20:21, Bartkoski,Dirk Alan wrote:
> Interesting. I don't think I have encountered this during my usage of
> FLUKA so far. Is there a FLUKA course that deals with this?
>
> ______________________________________________________________________
> _________
> Dirk A. Bartkoski, Ph.D.
> Research Scientist | Division of Radiation Oncology
>
> T. Boone Pickens Tower (FCT8.5007)
> 1515 Holcombe Blvd.
> Unit 1420
> Houston, TX 77030
> (713)794-5026
>
>
> -----Original Message-----
> From: me_at_marychin.org [mailto:me_at_marychin.org]
> Sent: Thursday, March 30, 2017 8:31 PM
> To: Bartkoski,Dirk Alan <DABartkoski_at_mdanderson.org>
> Cc: FLUKA Discussion List <fluka-discuss_at_fluka.org>
> Subject: Re: [fluka-discuss]: Bremsstrahlung Dose Isolation
>
> The technique is called 'latching'. This is what ISPUSR is for. At
> every bremsstrahlung event (identified with ICODE in mgdraw.f), set
> ISPUSR.
> This ISPUSR value:
> - will remain with the bremsstrahlung photon;
> - will be propagated to all the progenies of this bremsstrahlung
> photon, till the end of the history.
>
> You may then use ISPUSR to filter the dose deposition in comscw.f, and
> use USRBIN as usual.
>
> ISPUSR is an array. For this purpose only an element of the array is
> necessary.
>
> :) mary
>
> On 2017-03-31 01:02, Bartkoski,Dirk Alan wrote:
>> I am modeling electron beams on water and looking at different dose
>> distributions and percent depth dose characteristics. I want to
>> separate out the bremsstrahlung contribution to the dose and compare
>> the total dose with the bremsstrahlung component. What would be the
>> best way to measure only bremsstrahlung dose or the dose without the
>> bremsstrahlung?
>>
>> _____________________________________________________________________
>> _
>> _________
>>
>>
>> _DIRK A. BARTKOSKI, PH.D._
>>
>> RESEARCH SCIENTIST | DIVISION OF RADIATION ONCOLOGY
>>
>> _T. Boone Pickens Tower (FCT8.5007)_
>>
>> _1515 Holcombe Blvd._
>>
>> _Unit 1420_
>>
>> _Houston, TX 77030 _
>>
>> _(713)794-5026_
>>
>> The information contained in this e-mail message may be privileged,
>> confidential, and/or protected from disclosure. This e-mail message
>> may contain protected health information (PHI); dissemination of PHI
>> should comply with applicable federal and state laws. If you are not
>> the intended recipient, or an authorized representative of the
>> intended recipient, any further review, disclosure, use,
>> dissemination, distribution, or copying of this message or any
>> attachment (or the information contained therein) is strictly
>> prohibited. If you think that you have received this e-mail message
>> in error, please notify the sender by return e-mail and delete all
>> references to it and its contents from your systems.
> The information contained in this e-mail message may be privileged,
> confidential, and/or protected from disclosure. This e-mail message
> may contain protected health information (PHI); dissemination of PHI
> should comply with applicable federal and state laws. If you are not
> the intended recipient, or an authorized representative of the
> intended recipient, any further review, disclosure, use,
> dissemination, distribution, or copying of this message or any
> attachment (or the information contained therein) is strictly
> prohibited. If you think that you have received this e-mail message in
> error, please notify the sender by return e-mail and delete all
> references to it and its contents from your systems.
>
> ______________________________________________________________________
> ____ You can manage unsubscription from this mailing list at
> https://www.fluka.org/fluka.php?id¬c_info
    The information contained in this e-mail message may be privileged, confidential, and/or protected from disclosure. This e-mail message may contain protected health information (PHI); dissemination of PHI should comply with applicable federal and state laws. If you are not the intended recipient, or an authorized representative of the intended recipient, any further review, disclosure, use, dissemination, distribution, or copying of this message or any attachment (or the information contained therein) is strictly prohibited. If you think that you have received this e-mail message in error, please notify the sender by return e-mail and delete all references to it and its contents from your systems.
    ?��?�f�j?��˛���ب����b�f��)�+-j�m��?�?0~[�j����n��a�'Zqȧ~

(Ƨځ맲r*'~&x%Zm 0nߖi'iw
Received on Sat May 27 2017 - 11:23:51 CEST

This archive was generated by hypermail 2.3.0 : Sat May 27 2017 - 11:24:27 CEST