Re: [fluka-discuss]: K-alpha emissions of Copper

From: Santana, Mario <msantana_at_SLAC.Stanford.EDU>
Date: Fri, 2 Jun 2017 21:31:37 +0000

Hi Marine,

Your k-alpha lines are in the order of 8 keV, right? So, then you want to run with PRECISIO as your DEFAULT (so as to have the right physics such as photoelectric edge, fluorescence…) and additionally you have to set your transport of e+/e-/gamma to something like 1 keV by using the EMF-CUT cards.


-Mario


On 6/2/17, 11:49 AM, "owner-fluka-discuss_at_mi.infn.it on behalf of wurth" <owner-fluka-discuss_at_mi.infn.it on behalf of wurth_at_ipno.in2p3.fr> wrote:

    Hello Marine,
    
    DETECT or USRTRACK cards should be suitable in that case.
    
    Hope it helps.
    Best.
    Sebastien.
    
    Le 2017-06-02 19:04, Marine Huault a écrit :
> Dear Users,
>
> I am beginner in FLUKA. I simulate a proton beam of 1 MeV going on a
> Copper target and I want to detect k-alpha emissions of Copper. Do you
> know which card I have to use ?
>
> Thank you very much.
>
> Marine Huault
>
> Marine Huault
> Scientist
> CENTRO DE LASERES PULSADOS
> Building M5. Science Park USAL
> Calle del Adaja, 8.
> 37185 Villamayor, Salamanca. SPAIN
    
    __________________________________________________________________________
    You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
    
    

(Ƨځ맲r*'~&x%Zm 0nߖi'iw
Received on Sat Jun 03 2017 - 00:27:03 CEST

This archive was generated by hypermail 2.3.0 : Sat Jun 03 2017 - 00:27:07 CEST