Hi,
I am calculating the electron dose distribution for I-131 in small spheres of water.
To simulate my radioactive source, I am using the RADDECAY card in semi-analogue mode and the decay score and everything is going well.
Is there a way to get the different contributions of Auger electrons, conversion electrons and beta electrons from my I-131 source inside my water sphere?
I have not seen something like that in the mgdraw routine.
Thanks in advance.
Jean-Emmanuel
_______________________________________________________________
Jean-Emmanuel Groetz
Laboratoire Chrono-Environnement UMR CNRS 6249
Université de Franche-Comté
16 route de Gray
25030 Besançon Cedex France
Phone : +33 (0)3 81 66 65 07
mailto: jegroetz_at_univ-fcomte.fr
http://chrono-environnement.univ-fcomte.fr/spip.php?article1537
_______________________________________________________________
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Fri Mar 23 2018 - 17:53:16 CET