Dear FLUKA users
I'd like to get ambient dose equivalent in ICRU sphere by using
deq99c.f while the source is Proton with a spectrum of energy which is
defined by source.f.
I want to know how can get total dose equivalent from all secondaries
which are included deq99c.f ? Is it enough to set the particle type
to be scored= 201 (all particle) or I should calculate dose equivalent
for each secondary separately, then add them up? How about generalised
particle 208 (energy)?
And the other question, among USRBIN,USRBDX and USRTRACK which one is
recommended to calculate dose equivalent?