Hello,
This functionality does not exist in FLUKA. However, you may convolute the tracklength values with existing cross section evaluated data and obtain reaction rate.
Kind regards,
Ricardo
//Ricardo dos Santos Augusto
TRIUMF-EH&S
Office: +1 604 222 10 47 (6375)
4004 Wesbrook Mall,
Vancouver, BC V6T 2A3, Canada//
________________________________
De : owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] de la part de 李立华 [13691416247_at_ciae.ac.cn]
Envoyé : dimanche 5 avril 2020 10:40
À : fluka_collaboration
Objet : [fluka-discuss]: to obtain reaction rate
Dear Fluka experts:
I want to calculate the reaction rate in one region,the formula is like this:
[cid:72736cce$1$1714974047d$Coremail$13691416247$ciae.ac.cn]
V means volume of the region
cross-section(E) means the cross section of particle with the materials in the region
n means atomic nucleus number of the material, if the material has a few isotopes, n shauld be like the [cid:598552eb$2$171497c43a0$Coremail$13691416247$ciae.ac.cn]
it can be obtained using USRTRACK card,but how to multiply cross section in fluka2020?
in mcnp/x, it can be done by multiply MT(as in ENDF-6) or FM(mcnp/x only)
in phits, it can be done by using Multiplier section(the cross section data need user to obtain)
in geant4,it can be done by multiply cross section data
do fluka2020 obtain this function?
with best regards!
请注意:在您阅读本邮件时,如您了解本邮件内容涉及商业秘密,请您遵守与发信人的商务约定,保守商业机密。如您发现本邮件内容涉及重要商业秘密或与国家秘密相关,请您即刻联系发信人,确认邮件内容是否适于通过互联网传递。
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Sun Apr 05 2020 - 19:42:54 CEST