RE: Integrating a USR-1D plot

From: Joachim Vollaire <joachim.vollaire@cern.ch>
Date: Fri Sep 12 2008 - 00:13:42 CEST

Hi Joannes
The fasted way to do it is to look in the file with the _sum.lis
extension which is created when you average the results of your
different runs (with flair or with ustsuw). For each detector (USRTRACK)
the header looks like this :
  **** ex_4_usrtrack_55 ****

  Total primaries run: 5000

    Total weight of the primaries run: 5000.

  Detector n: 1 TrChH
     (Volume: 628.309998 cmc,
      distr. scored: 218 ,
      from reg. 4 )

     Tot. response (p/cmq/pr) 1.7793756E-02 +/- 0.5521924 %
     ( --> Track l. (cm/pr) 11.17999 +/- 0.5521924 % )

The total response is the value you are interested in.... and cherry on
the cake you even have the statistical uncertainty
Cheers
Joachim

-----Original Message-----
From: owner-fluka-discuss@mi.infn.it
[mailto:owner-fluka-discuss@mi.infn.it]=20
Sent: jeudi, 11. septembre 2008 12:05
To: fluka-discuss@fluka.org
Subject: Integrating a USR-1D plot

Hello erverybody.
I am using the USRTRACK card to get the fluence of ALL-CHARged =20
particles. Also I am using the FLAIR interface. Now, having my =20
simulation run, I am plotting my fluence graph. To analyze my results =20
I would like to integrate over this. Do you have suggestions how to do =20
that? FLAIR itself does not have such an option for a USR-1D plot and =20
I am wandering what is the easiest way to do so...
Thank you very much, Johannes
Received on Fri Sep 12 11:02:19 2008

This archive was generated by hypermail 2.1.8 : Fri Sep 12 2008 - 11:02:19 CEST