Re: ustsuw errors for AMB74 estimation ; but none for fluence estimation

From: Stefan Roesler <sroesler@mail.cern.ch>
Date: Fri Sep 12 2008 - 18:48:39 CEST

Hi Sunil,

Your last USRTRACK detector has 6600 bins (not 600) which exceeds the
maximum number of allowed in ustsuw. Did you try with a dimension of 7000
or bigger?

cheers
stefan

On Fri, 12 Sep 2008, Sunil C wrote:

> Hi All
> I am getting the following error when i use the 'ustsuw' to access the data
> written to the file *fort.37.
> -------------------error message-------------------------
> Type the input file: dose001_fort.37
> Estimation of neutron dose
> DATE: 9/12/ 8, TIME: 13:59:43
> 10.
> 10
> Subscript out of range on file line 243, procedure ustsuw.f/MAIN.
> Attempt to access the 3001-th element of variable accumg.
> Abgebrochen
> *----------------------------end of error message-----------
> I tried changing the "PARAMETER (NMXEBN =2500 ) to different values (at
> present at 2500) and tried cutting down the number of energy bins to
> differet sizes. I have had no problems before with 600 bins using the same
> program. Infact on a different detetcor it runs very well. The input part of
> this scoring is attached as 'input_part1.txt'. However, similar input with
> fluence scoring instead of dose runs very well even with larger energy bins
> (input part attached as 'input_part2.txt').
> Both refers to the same detector but scoring different quantities.
>
> Is there a parameter that can be changed in the ustsuw.f that can solve
> this?
>
> Thanks for all the help
> Best Regards
> Sunil
>

-- 
___________________________________
Stefan Roesler
CERN, SC/RP
CH-1211 Geneva 23
Switzerland
Phone:  +41-22-7679891
Fax:    +41-22-7669639
E-mail: Stefan.Roesler@cern.ch
Received on Fri Sep 12 20:10:06 2008