Hello
you have to set the y "weighting" separately for each detector
Paola
> Dear FLUKA experts,
>
> I have to do a multiplot. All the input coming from the different
> detectors have to be multiplied with the bin energy width. So, I pick
> the option for the plot y*Dx. However, when I switch detector this is
> automatically changed to y*<x>. I am mixing data coming from another
> software, MCNP, so I cannot use this second option because those are
> already formatted in that way. There is a a wasy to switch off this
> automatic change?
>
> Best regards and thank you for your time, Alessandro Calamida.
>
>
> --
> Questa e-mail รจ stata controllata per individuare virus con Avast
> antivirus.
> https://www.avast.com/antivirus
>
>
> __________________________________________________________________________
> You can manage unsubscription from this mailing list at
> https://www.fluka.org/fluka.php?id=acc_info
>
Paola Sala
INFN Milano
tel. Milano +39-0250317374
tel. CERN +41-227679148
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Thu Jun 25 2020 - 16:07:44 CEST