Re: [fluka-discuss]: Air activation products

From: Paola Sala <paola.sala_at_mi.infn.it>
Date: Fri, 14 May 2021 16:32:41 +0200

Dear Taiee,

I would say both. Much depends on the ventilation,  indeed those
nuclides  are often captured by  filters of the ventilation system.

Cheers

Paola

On 5/14/21 1:26 PM, Liang, Taiee wrote:
> Dear FLUKA mailing list,
>
> I have a few curiosity questions about certain nuclides produced via air
> activation. I have performed calculations of produced nuclides in air from
> 14 GeV e- via RESNUCLE scoring (attached table).
>
> In a physical sense, what happens to products such as nuclides such as
> Be-7 and P-32, which are not gaseous? Are they even transported by air
> ventilation? Do they bind themselves to dust in air and are carried away?
> Or do they bind to surfaces within the room they are produced in? Maybe
> both...?
>