Re: activation and dose-eq calculations

From: Paola Sala <paola.sala_at_mi.infn.it>
Date: Mon, 22 Jun 2009 08:58:34 +0200 (CEST)

Dear Lior
with the AUXSCORE card one selects the particle that is depositing
the energy, not its parent. In the case of dose from induced
radioactivity, the particles depositing the energy are electrons/photons
from radioactive decay, not the radioactive nucleus itself. Therefore, if
you select Iron with the auxcard, you'll get a zero result.
When one uses the DCYSCORE card,
results are per unit time , pSv/sec
Paola
> Good Morning,
> I am trying to simulate a neutron beam hitting a stainless steel
> target and I want to see the activation products and the EQ-Dose
> 10 cm from the target. The target is irradiated for 10 minutes
> and allowed a cooling time of 2 minutes.
> I have done a manual calculation of the activation products and
> dose and received different results from the FLUKA output file.
> For example, the dose rate 10 cm from the target from the Fe-56
> after 2 minutes cooling time is calculated to be 3474.0248 and
> when I enter A and Z for Fe-56 in the auxscore card for DOSE-EQ
> I get zero.
> What could be the problem?
> the input file is attached.
> Another question is are the results of the USRBIN DOSE-EQ in pSv
> or pSv/sec?
> thank you for your time
> Lior Cahana
>
>