Re: Which Card to Score the energy depostion event by event (Pulse Amplitude spectrum)

From: Francesco Cerutti <Francesco.Cerutti_at_cern.ch>
Date: Fri, 4 Sep 2009 23:55:42 +0200

Dear Xu Lijun,

as for your first question, I'm afraid that I missed your point, so I
would like to kindly ask you to clarify in more detail the information you
need to extract and in which sense you failed. With EVENTBIN you get the
energy deposited in a cell after each primary particle, why cannot the
respective channel be identified at post-processing level?

As for the unformatted output reading, please have a look at the EVENTBIN
and USRBIN cards in the manual, where instructions are reported

Kind regards

Francesco

**************************************************
Francesco Cerutti
CERN-EN/STI
CH-1211 Geneva 23
Switzerland
tel. ++41 22 7678962
fax ++41 22 7668854

On Thu, 3 Sep 2009, Xu Lijun wrote:

> Dear Fluka Experts:
>
> When I utilize the scoring function of energy deposition event by event to
> simulate the pulse amplitude of TEPC (Tissue Equvilent Proportional Counter),
> I failed because I couldn't score energy deposition event by event between given energy
> limits distributed over ,e.g.1024 channels. Could you tell me which scoring card
> should I use?
>
> Another question is that how I can read the result of EVENTBIN card if I
> use the "bin unit". Thank you!
> Best wishes for you!
>
> XuLijun
> 2009-08-31
Received on Sat Sep 05 2009 - 11:46:58 CEST

This archive was generated by hypermail 2.2.0 : Sat Sep 05 2009 - 11:47:29 CEST