Re: si1mevne

From: <Andrea.Mairani_at_mi.infn.it>
Date: Mon, 23 Aug 2010 12:36:53 +0200 (CEST)

Dear User,
  I've looked at your input and I've seen that you are using the SOURCE
card but I did not find the source routine in the attachments of your
emails. So I cannot really reproduce your simulation. Anyway, I see that
you are using NEW-DEFA as default. With NEW-DEFA the particle transport
threshold is set at 10 MeV except for neutrons that is set at 1E-5 eV. So
I suggest you to use for example the PRECISION default.
Let us know if you have any improvements.
Andrea

> Dear Fluka experts and users
>
> I got an output from USRTRACK score with SI1MEVNE as a particle. Then I
> plotted my result for 5 inp file and saw a break at 20 MeV in the all of
> them. I can't understand the reason of it but I guess it 's resulted of
> FLUKA (especially transport part). I attached my plot and inp file, source
> .
> Please help me.
>
> Regards.
>
> Mojdeh Anjom
>
Received on Mon Aug 23 2010 - 14:48:23 CEST