Re: conditional scoring with FLUSCW using a flag in input file

From: Alberto Fasso' <fasso_at_mail.cern.ch>
Date: Mon, 17 Oct 2011 17:21:49 +0200

Hi Daniel,

you can use the command USRICALL (see manual).
That command calls a user routine USRINI with 6 WHATs to be defined by the user.
If you want those WHATs to be available also in FLUSCW, you can insert in
both routines a COMMON with those values.

Alberto

On Mon, 17 Oct 2011, Sanchez Parcerisa, Daniel wrote:

> Hello,
>
> I am using FLUSCW for some user-defined fluence scoring problem. I would like
> to choose at run time between two possible modes of scoring using a flag in
> the input file (in the same way that the source.f routine can be controlled by the WHASOU(i)
> user variables, but I can't find a way to do it, since the WHASOU(i) variables aren't seen
> from the FLUSCW routine (even including SOURCM commons).
> Are there some user variables that can be read from the input file and passed on to FLUSCW?
>
> Thank you very much
>
> Daniel Sanchez Parcerisa
> PARTNER Early Stage Researcher
>
> Siemens AG
> Healthcare Sector
> Imaging & IT Division
> H IM PT OP TI
> Hofmannstr. 26
> 91052 Erlangen, Germany
Received on Tue Oct 18 2011 - 09:26:18 CEST

This archive was generated by hypermail 2.2.0 : Tue Oct 18 2011 - 09:26:19 CEST