sum files not reporting the final units after applying conversion coefficients via an AUXSCORE card

From: Mina Nozar <nozarm_at_triumf.ca>
Date: Mon, 24 Oct 2011 11:50:59 -0700

Hi everyone,

I have two questions on reporting of units in the summary (_sum.lis) files.

Looking at Neutron Fluence (unit 33) and Neutron Dose Eq (unit 32) using the respective cards below,
I see the same units reported for both cases. i.e. Tot. response (p/cmq/pr).

Firstly, I am not sure what "p" in the above unit stands for. It should be particle track length. True?
Secondly, why does the output file for unit 32 also report the results in the same units instead of pSv/GeV.prim?
Is it a fact that FLUKA doesn't handle unit conversions in the sum. files?

Thanks and best wishes,
Mina

* Neutron fluence. No Ambient Dose equivalent conversion factor applied. Results in cm/GeV.cm^3.prim)
USRTRACK -1. DOSE-EQ -33. rAirDetE 785398. 260.DTELE
USRTRACK 0.02 1E-14 &
USRTRACK -1. DOSE-EQ -33. rAirDetE 785398. 10.DTEHE
USRTRACK 0.110 0.02 &
AUXSCORE USRTRACK NEUTRON DTELE DTEHE 1.0

* Ambient Dose AMB74 conv. factor applied. Results in pSv/(GeV.prim)
USRTRACK -1. DOSE-EQ -32. rAirDetE 785398. 260.DTEastLE
USRTRACK 0.02 1E-14 &
USRTRACK -1. DOSE-EQ -32. rAirDetE 785398. 10.DTEastHE
USRTRACK 0.110 0.02 &
AUXSCORE USRTRACK NEUTRON DTEastLE DTEastHE 1.0AMB74
Received on Mon Oct 24 2011 - 22:49:07 CEST