Dear Fluka Experts and
Prof. Dr. "Alberto Fasso,
EMail: fluka-discuss_at_fluka.
Thank you very much for your response to our question regarding the thermal neutrons detection via PPAC detector.
Upon receiving your following suggestions:
//////////////////////////////
As a default, charged fragments produced by thermal neutrons are not
transported: that is why you "see" them at the gas-gap where they are
produced, but not at the PPAC's gas gap. But for 6-Li it is possible to
make an exception by requesting pointwise cross sections: use LOW-NEUT
command with WHAT(6) = 1. (Leave all other WHATs = 0).
In this way, 3-H and 4-He will be transported and will be detected far from the production point.
//////////////////////////////
We employed them into out Fluka input file(attached), and tried. However we could not still found the 3-H and 4-He, secondaries at the gas gaps.
Could you please have a look into our attached files.
With best wishes,
Dr. M. Jamil and Kim Hyun
Gee
Konkuk University,
EMail: mjamil_at_konkuk.ac.kr, erwin.hyeongi_at_gmail.com
This archive was generated by hypermail 2.3.0 : Thu May 02 2013 - 00:53:14 CEST