Re: [fluka-discuss]: Turning off biasing with RADDECAY

From: paola sala <paola.sala_at_cern.ch>
Date: Thu, 17 Oct 2013 13:37:57 +0200

Hello
The value 0 is ignored. To set bias for decay radiation only the flag
should be set to 2 (sse manual :

2.0 = applied to decay radiation only)

cheers
Paola
On 10/17/2013 12:12 PM, Paul Miyagawa wrote:
> Hello,
>
> I am trying to turn off biasing for both prompt and decay radiation
> using WHAT(4) of the RADDECAY card. I am finding that any flags I set
> to 0 are treated as 1 (i.e., biasing is turned on for prompt radiation
> for those particles). Is this expected, and if so then does that mean
> it is impossible to turn off biasing for both prompt and decay
> radiation? Thanks for any help.
>
> Cheers,
> Paul
Received on Thu Oct 17 2013 - 14:23:16 CEST