RE: [fluka-discuss]: Turning off biasing with RADDECAY

From: Paul Miyagawa <Paul.Miyagawa_at_cern.ch>
Date: Thu, 17 Oct 2013 11:40:36 +0000

Hello Paola,

Thank you for your suggestion. Unfortunately it seems I didn't make myself clear. I want biasing OFF for prompt radiation and OFF for decay radiation as well (i.e., I do NOT want biasing on at all).

Cheers,
Paul

From: Paola Sala
Sent: 17 October 2013 12:38
To: Paul Miyagawa
Cc: fluka-discuss_at_fluka.org
Subject: Re: [fluka-discuss]: Turning off biasing with RADDECAY

Hello
The value 0 is ignored. To set bias for decay radiation only the flag
should be set to 2 (sse manual :

2.0 = applied to decay radiation only)
cheers
Paola
On 10/17/2013 12:12 PM, Paul Miyagawa wrote:
Hello,

I am trying to turn off biasing for both prompt and decay radiation using WHAT(4) of the RADDECAY card. I am finding that any flags I set to 0 are treated as 1 (i.e., biasing is turned on for prompt radiation for those particles). Is this expected, and if so then does that mean it is impossible to turn off biasing for both prompt and decay radiation? Thanks for any help.

Cheers,
Paul
Received on Thu Oct 17 2013 - 14:27:12 CEST