Re: [fluka-discuss]: the problem of Ecut

From: Anna Ferrari <a.ferrari_at_hzdr.de>
Date: Mon, 21 Apr 2014 19:16:42 +0200

Dear user,

as you can read in the manual you can set via the EMFCUT card two kind of
cutoff for electrons/positrons and photons: the transport cutoff (if
sdum=blank) and the production cutoff (if sdum=PROD-CUT).
You did not send your input file, but it seems that you have set only the
first one: Ecut in the output file is the transport cutoff and gives you
correctly 0.711 MeV. Ae is the electron production cutoff, if you want a
desired value you have to set it in your input file.

Kind regards,
Anna


Am Sun, 20 Apr 2014 21:55:37 +0800 schrieb "韩俊杰" <hanjunj_at_mail2.sysu.edu.cn>:
> Dear fluka-discuss:
> When I used EMF-cut to set the energy thresholds, I set electron cut off
>200keV (kinetic) for water.Then after run the input file,it create a file
>named XX001.out. I tried to read it:
>
> 1 Quantities/Biasing associated with each media:
>
>
> WATER
> Rho = 1.00000 g/cm**3 Rlc= 36.0830 cm
> Ae = 0.610999 MeV Ue = 5060.98 MeV
> Ap = 5.000000E-03 MeV Up = 5060.47 MeV
> dE/dx fluctuations activated for this medium, level 1
> below the threshold for explicit secondary electron production
> (up to 2I discrete levels, up to 2 K-edges)
>
> 1 Correspondence of regions and EMF-FLUKA material numbers and names:
> Region EMF FLUKA
>
> 1 0 VACUUM 1 BLCKHOLE
> Ecut = 0.0000E+00 MeV, Pcut = 0.0000E+00 MeV, BIAS = F, Ray. =
>F, S(q,Z) = F, Pz(q,Z) = F
> 2 0 VACUUM 2 VACUUM
> Ecut = 0.0000E+00 MeV, Pcut = 0.0000E+00 MeV, BIAS = F, Ray. =
>F, S(q,Z) = F, Pz(q,Z) = F
> 3 1 WATER 28 WATER
> Ecut = 7.1100E-01 MeV, Pcut = 5.0000E-03 MeV, BIAS = F, Ray. =
>T, S(q,Z) = T, Pz(q,Z) = T
> 4 2 POJKGUOO 27 POJKGUOO
> Ecut = 7.1100E-01 MeV, Pcut = 5.0000E-03 MeV, BIAS = F, Ray. =
>T, S(q,Z) = T, Pz(q,Z) = T
> 5 1 WATER 28 WATER
> Ecut = 7.1100E-01 MeV, Pcut = 5.0000E-03 MeV, BIAS = F, Ray. =
>T, S(q,Z) = T, Pz(q,Z) = T
>
> After read it ,I felt confused: Ae = 0.610999 MeV in water, but
>Ecut = 7.1100E-01 MeV, which is right for E-cut ? 0.610999 or 7.1100E-01
>? If 7.1100E-01 is right ,what does Ae = 0.610999 MeV mean?



~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Anna Ferrari
Institute of Radiation Physics
Helmholtz-Zentrum Dresden-Rossendorf e.V.