Re: [fluka-discuss]: Energy deposited: AUXSCORE vs SCORE

From: Francesco Cerutti <Francesco.Cerutti_at_cern.ch>
Date: Mon, 28 Jul 2014 18:25:33 +0200

Hi Warit,

indeed SCORE and USRBIN per region give exactly the same output and I
cannot find any evidence of a different behavior.
Can you please send your input file to crosscheck your findings?

Best

Francesco

**************************************************
Francesco Cerutti
CERN-EN/STI
CH-1211 Geneva 23
Switzerland
tel. ++41 22 7678962
fax ++41 22 7668854

On Fri, 25 Jul 2014, Mitthumsiri, Warit wrote:

>
> Dear all,
>
> I would like to record the energy deposited in each region. I tried comparing the output from these cards:
>
> *******
> SCORE 208.0 211.0
> *******
>
> and
>
> *******
> USRBIN 12.0 EM-ENRGY 26.0 299.0 EMEdp
> USRBIN 18.0 1.0 &
> AUXSCORE USRBIN ALL-PART EMEdp
> USRBIN 12.0 ENERGY 28.0 299.0 TotEdp
> USRBIN 18.0 1.0 &
> AUXSCORE USRBIN ALL-PART TotEdp
> *******
>
> which should have given the same output (energy deposited / beam particle, without normalization by region volume), but they give significantly different output. The output from the SCORE card looks more correct. Does anyone have any idea?
>
> -Warit
>
>
Received on Mon Jul 28 2014 - 20:03:26 CEST