[fluka-discuss]: Unequal value of alpha and Lithium in RESNUCLEi

From: <meghms_at_barc.gov.in>
Date: Thu, 18 Jun 2015 12:22:40 +0530

Dear Fluka experts,
                    I am using RESNUCLEi card to find out the number of
Lithium and alpha produced in a spherical volume
(filled with BF3 gas having density of 9.85e-4 g/cc,
100% B-10) for the thermal neutron (0.025 eV). But the
(number of alpha/primary /cc) and (number of
lithium/primary /cc) are coming different. The number
of alpha is less (by 20% approximately) than that of
lithium. Using PHYSICS (COALESCE and EVAPORAT) card
also the results are coming same. What I understand
is that the numbers should be same. Input files with
the associated results are attached below.
[The fluka version used is “fluka2011.2c-linuxAA.tar.gz” in flair].
Any help will be heartily appreciated..

Thanks,
Meghnath Sen
BARC, INDIA