Re: [fluka-discuss]: USRBIN 1D projection plot

From: Hamideh Jalali <jalali.hb_at_gmail.com>
Date: Thu, 10 Sep 2015 10:48:33 +0430

Dear Stefan

Actually I didn't set the upper limit for X because I just wanted to have
dose equivalent behind lateral shield wall at x=151.2 (right side) and x=
-152.1(left side) near beam height (y=-0.5).
Maybe I am wrong in using 1D projection plot.

Regards
Hamideh

On Tue, Sep 8, 2015 at 8:29 PM, Stefan Roesler <sroesler_at_mail.cern.ch>
wrote:

> Dear Hamideh
>
> Did you define in Flair/Plot/Projection&Limits and upper limit in X? On
> your screen-shots this info is hidden below the graphs...
>
> If not, I guess Flair plots in one case the average in x from -151.2 to
> 210 (i.e., across the target room) and in the other case from 151.2 to 210
> (i.e. only outside of the target room)
>
> Defining an upper limit in x gives the expected results..
>
> Cheers
> Stefan
>
> ___________________________________
>
> Stefan Roesler
> CERN, DGS-RP
> CH-1211 Geneva 23
> Switzerland
>
> Phone: +41-22-7679891
> Fax: +41-22-7669639
> E-mail: Stefan.Roesler_at_cern.ch
>
>
> On Mon, 7 Sep 2015, Hamideh Jalali wrote:
>
> Dear Stefan
>>
>> Thanks for your attention on my question.
>> Please find attached my input.
>>
>> Regards
>> Hamideh
>>
>> On Mon, Sep 7, 2015 at 1:52 PM, Stefan Roesler <Stefan.Roesler_at_cern.ch>
>> wrote:
>>
>> Dear Hamideh
>>
>>
>>
>> Could you please post input and flair file? The question is
>> difficult to
>> understand from your below description.
>>
>>
>>
>> Cheers
>>
>> Stefan
>>
>>
>>
>> From: owner-fluka-discuss_at_mi.infn.it [mailto:
>> owner-fluka-discuss_at_mi.infn.it] On
>> Behalf Of Hamideh Jalali
>> Sent: 07 September 2015 06:59
>> To: fluka-discuss <fluka-discuss_at_fluka.org>
>> Subject: [fluka-discuss]: USRBIN 1D projection plot
>>
>>
>>
>> Dear FLUKA Experts
>>
>>
>>
>> In my problem an inclined Si target has been placed in a room (x:-150 to
>> 150, y:-50
>> to 250, z: 0 to 1000 cm) and has symmetry to the lateral walls. The
>> beam(produced gas
>> bremsstrahlung) is in z direction with x and y coordinate of 0.
>>
>> I would like to score dose equivalent along the room behind lateral
>> walls in near
>> beam height. To have so, I used 1D projection plot of USRBIN. I expected
>> to have the
>> same results in both sides of the room but the plots are completely
>> different. They
>> are attached.
>>
>> Please guide me to know where I am wrong.
>>
>>
>>
>> Kind Regards
>>
>> Hamideh
>>
>>
>>
>>


__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Thu Sep 10 2015 - 10:07:02 CEST

This archive was generated by hypermail 2.3.0 : Thu Sep 10 2015 - 10:07:04 CEST