Re: [fluka-discuss]: Problems of the New version flupix-2011.2c-4_flair-2.2-1

From: Stefan Roesler <sroesler_at_mail.cern.ch>
Date: Mon, 27 Jun 2016 23:07:24 +0200

Dear Tao Yang

I have run your inputs on a Laptop running Linux (and not via flupix) and
get
1. the expected BEAMPART fluence
2. a color fluence plot resembling the cascade evolution.

Thus, your observations could be related to you installation.

Cheers
Stefan


On Wed, 22 Jun 2016, YANG Tao wrote:

>
> Hello, everyone!
>
> Recently, I find there are some problems of the new
> version  flupix-2011.2c-4_flair-2.2-1. I don't know whether you have the
> problems or not.
>
> 1. The 1 MeV gamma rays were directed  towards a simple cuboid lead block.
>  USRBDX score card has been used to obtain the transmission values, I/I0,
> where I0 and I are the incident and attenuated photon intensities.
> Theoretically, I0 is  1 photon/primary since the incident photon will all
> penetrate the front surface of the lead block, however,  the result (31BIN,
> "rushe") always give ZERO result, it's confusing, where did the photons go?
> and I get the correct result running on the server workstation. The input
> file is gamm.inp
>
> 2. The USBIN results could plot a colorful picture in the old version of
> flupix as shown in figure1, however, the picture can only show the pink
> color shown in figure2 for the same merging files. The input file is blm.inp
>   
>
> Could someone help me in these questions please?
>  
> Thank you.
>  
> With the best regards,
>  
>
> Tao Yang
>
> CAS
>
>
>

__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Tue Jun 28 2016 - 00:43:45 CEST

This archive was generated by hypermail 2.3.0 : Tue Jun 28 2016 - 00:43:46 CEST