Quick launch:
Last version:
News:
--
New Fluka Major Release
|
[ <--- prev -- ] [ HOME ] [ -- next ---> ] TIME-CUTSets transport time cutoffs for different particles
WHAT(1) = transport time cutoff (nsec) Default: no cut off WHAT(2) = transport time cutoff delay (nsec) Default = 0.0 WHAT(3) = material number for the "start" signal from which time is measured (useful for calorimetry) (Not implemented at present) Default: "start" at creation time WHAT(4) = lower bound of the particle numbers for which the transport time cutoff and/or the start signal is to be applied ("From particle WHAT(4)..."). Default = 1.0 WHAT(5) = upper bound of the particle numbers for which the transport time cutoff and/or the start signal is to be applied ("...to particle WHAT(5)..."). Default = WHAT(4) if WHAT(4) > 0, all particles otherwise. WHAT(6) = step length in assigning numbers. ("...in steps of WHAT(6)"). Default = 1.0 SDUM : not used Default (option TIME-CUT not given): no time cutoff for particle transport Notes:
Example: *...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8 TIME-CUT 3000.0 0.0 0.0 8.0 0.0 0.0 * Stop transporting neutrons after 3000 nsec |
© FLUKA Team 2000–2024