From: owner-fluka-discuss@fisica.unimi.it
Date: Wed Feb 25 2004 - 01:23:01 CET
Dear fluka user,
The attachment is my input file. In my mind, the result got by USRBIN and USRTRACK
is the same(divided the energy binning). But actually the result is not right. Who
can help me?
Thanks a lot
The result:
USRTRACK:
Track n. 1 "photon " , generalized particle n. 7, region n. 4
detector volume: 1.0000E+00 cm**3
linear energy binning from 0.0000E+00 to 1.5000E-02 GeV, 1 bins (
1.5000E-02 GeV wide)
Data follow in a vector A(ie), format (1(5x,1p,10(1x,e11.4)))
6.6418E+01
USRBIN
Cartesian binning n. 1 "photon " , generalized particle n. 7
X coordinate: from -5.0000E-01 to 5.0000E-01 cm, 1 bins ( 1.0000E+00 cm
wide)
Y coordinate: from -5.0000E-01 to 5.0000E-01 cm, 1 bins ( 1.0000E+00 cm
wide)
Z coordinate: from 0.0000E+00 to 1.0000E+00 cm, 1 bins ( 1.0000E+00 cm
wide)
Data follow in a matrix A(ix,iy,iz), format (1(5x,1p,10(1x,e11.4)))
accurate deposition along the tracks requested
this is a track-length binning
9.2276E-02
Zhen Wu
2004.2.24