Re: Error message explanation needed

From: Paolo MAESTRO (paolo.maestro@pi.infn.it)
Date: Wed May 25 2005 - 22:03:17 CEST

  • Next message: Katherine Harine: "Heavy Ion Fluence"

    Your guess is right.
    I have modified the source routine so that the energy of the
    primary particle is generated according to a power-law spectrum.
    As you explained, the error occurred any time the randomly-extracted
    energy overcame the BEAM card value.
    I solved the problem simply writing in the card a value greater than
    the upper limit of the spectrum.
    Thanks for your help

    Paolo

    On Wed, 25 May 2005, Giuseppe Battistoni wrote:

    > That error message means that you are sampling an energy greater than
    > the value declared in the BEAM card.
    > Are you using a source user routine? Are you using FLUKA with rqmd and
    > dpmjet?
    > The valued in the BEAM card is used by FLUKA as the maximum energy for
    > initial tabulation of cross sections , dE/dx etc.
    > If by chance you overcome that value the program goes crazy.
    >
    > Giuseppe
    >
    > On Thu, 19 May 2005, maestro wrote:
    >
    > > Date: Thu, 19 May 2005 18:17:53 +0200
    > > From: maestro <paolo.maestro@pi.infn.it>
    > > To: fluka-discuss@mi.infn.it
    > > Subject: Error message explanation needed
    > >
    > >
    > > Dear all,
    > > I am simulating relativistic ions interaction in a calorimeter .
    > > At a given point, my job gets into a never-ending loop
    > > during which the following message is written and repeated
    > > continuously in the myjob.err file:
    > > ------------------------------------------------
    > > Stepop, dp/dx=<0!! ij, mmat, ekin, dpdx0 -2 30 7621.6471 -0.000335210437
    > > *** Stepop: Trange < 0, Ij,Pla,Pthr -2 7632.81378 0.516069975
    > > Kaskad: Dool<0!!, DOOL,IJ,PLA,PLAOLD,EKIN,TUSTEP,TVSTEP,MMAT
    > > -1.67605039E-19 -2
    > > 7632.81378 7632.81378 7621.6471 5.E-16 5.E-16 30
    > > 0 GEODEN CALLED WITH AN ECONTR VALUE OF: -0.168E-18
    > > ICALL = 131 IJ = 208 MREG,NEWREG = 48 48 IEST = 0
    > > --------------------------------------------------
    > > Can you explain it ? I guess that the problem concerns material n. 30
    > > (C2H4 i.e. light polyetylene with density = 0.035 g/cm3)
    > > but I don't understand why.
    > > Maybe could it be related to a wrong mat.pemf card compilation ?
    > >
    > > Many thanks for your help.
    > > Cheers
    > > Paolo
    > >
    > >
    > >
    > > %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
    > > Dr. Paolo Maestro
    > > Physics Department & INFN
    > > University of Siena
    > > via Roma 56, 53100 Siena (Italy)
    > > Phone +39 050 2214356
    > > Fax +39 050 2214317
    > >
    > >
    >
    >


  • Next message: Katherine Harine: "Heavy Ion Fluence"

    This archive was generated by hypermail 2.1.6 : Thu May 26 2005 - 09:31:16 CEST