From: Giuseppe Battistoni (Giuseppe.Battistoni@mi.infn.it)
Date: Fri Jul 28 2006 - 14:37:48 CEST
"Abort called from CNCPRS reason LNUMRC = .FALSE. Run stopped!
STOP LNUMRC = .FALSE."
means that there was an error on the datacard.
In fact on the COMPOUND card there is an alignment error: the - sign
of -27,0 was on the last digit of the previous field (-0.15)
That's all
Ciao
Giuseppe
On Fri, 28 Jul 2006, Chiara D'Ambrosio wrote:
> Date: Fri, 28 Jul 2006 12:25:57 +0200
> From: Chiara D'Ambrosio <chiara.dambrosio@lnf.infn.it>
> To: fluka-discuss@fluka.org
> Subject: COMPOUND of compounds - volume fraction
>
> Hi FLUKA users!
> I'm trying to define a gas mixture made of Ar/CO2/CF4 with volume
> fraction equal to 45/15/40.
> I've separately defined the material and the constituent compound of the
> mixture and then I've put them together to form the mixture in a new
> COMPOUND card.
> Unfortunately, I guess I made something wrong; indeed, I got the
> following error message:
> "Abort called from CNCPRS reason LNUMRC = .FALSE. Run stopped!
> STOP LNUMRC = .FALSE."
> Is there anybody that can easily explain me how to give the correct
> volume fractions?
>
> Thanks!!!
>
> Chiara D'Ambrosio
> LNF - INFN Research Division
> Frascati (RM) - Italy
>
This archive was generated by hypermail 2.1.6 : Fri Jul 28 2006 - 14:48:30 CEST