From: Vasilis Vlachoudis (Vasilis.Vlachoudis@cern.ch)
Date: Wed Apr 25 2007 - 14:34:49 CEST
Hi Alessandro,
in the flukapro/(DETECT) file it defines the limit of the detect cards
NDTCMX to 10 and the bins to 1024.
Unfortunately to change the limit, all the routines using the "(DETECT)"
include must be recompiled.
Regards
Vasilis
Ing. Alessandro A. Porta wrote:
> Hy, someone could tell me whether card DETECT can define only up to 10
> detectors or not ?
> Apparently I found this limit performing some simulations but I wasn't able
> to find such a limit in any page of the manual.
>
> I would also take advantage of this mail to ask "FLUKA - fathers" to modify
> card DETECT in order to allow an arbitrary energy binning different from the
> present 1024.
>
> Thanks to all.
> Sincerely
> ______________________________________________
> 互户互户互户互户互户互
> ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
> Alessandro A. Porta, Ing., EQ III, Ph.D.
> CESNEF - Politecnico di Milano
> Via Ponzio 34/3 - 20133 Milano - Italy
> ph.: +39-02-2399-6365 / 6300
> fax. +39-02-2399-6309
> e-mail: alessandro.porta@polimi.it
> URL: http://www.radioprotezione.polimi.it
> ______________________________________________
> 互户互户互户互户互户互
> ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
>
>
>
>
>
This archive was generated by hypermail 2.1.6 : Wed Apr 25 2007 - 18:22:39 CEST