Re: Re: [fluka-discuss]: How to score energy depisition in an irregular body?

From: <shihy_at_ihep.ac.cn>
Date: Fri, 28 Apr 2017 14:36:09 +0800

Dear Sujoy,

Thanks for your help. Could you please provide an example for how to use region based scoring? Since the region is also inregular or complex.

Thanks a lot.

Shy Shi
 
From: Sujoy Chatterjee
Date: 2017-04-28 13:31
To: shihy_at_ihep.ac.cn
CC: Fluka Discussion list
Subject: Re: [fluka-discuss]: How to score energy depisition in an irregular body?
Dear ShyShi,
For irregular body you can use region based scoring as available with FLUKA. In case of energy deposition the unit is GeV. For dose, it is normalized per unit mass of the region and the unit is GeV/g.
 
with regards,
सुजॉय चटर्जी/Sujoy Chatterjee
भाभा परमाणु अनुसंधान केंद्र/Bhabha Atomic Research Centre
1/ए एफ विधान नगर/1/AF-Bidhannagar,
कोलकाता - 700064/Kolkata - 700064
फ़ोन/Ph: +91-33-23184343
फैक्स/Fax:+91-33-23346871
 
-----owner-fluka-discuss_at_mi.infn.it wrote: -----
To: fluka-discuss <fluka-discuss_at_fluka.org>
From: "shihy_at_ihep.ac.cn"
Sent by: owner-fluka-discuss_at_mi.infn.it
Date: 04/28/2017 10:19AM
Subject: [fluka-discuss]: How to score energy depisition in an irregular body?
 
Dear Experts,
 
I need to scoring the energy deposition and doseeq in an irregular body. It was difficult to use USRBIN card to do this. I tried to use USRTRACK card to score "ENERGY", but it gave a number in the unit of "GeV/cm2", how to transfer it to the unit "GeV/g"? Or is there a better way to do this?
 
BTW, what's the difference between "ENERGY" and "DOSE" in scoring?
 
Thanks a lot.
 
Shy Shi


__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Fri Apr 28 2017 - 09:33:31 CEST

This archive was generated by hypermail 2.3.0 : Fri Apr 28 2017 - 09:33:33 CEST