Hi Amit,
the default energy cuts of photons& electrons are too high for your problem.
You should consider lowering them with the use of the EMFCUT card.
Your problem is quite small in dimensions so you could go easily down to
1keV for photons and 3-5keV for electrons.
Also with such a small detector it would be nice to activate the single coulomb
scattering with the use of the MULSOPT card
Best
Vasilis
________________________________
From: owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] on behalf of Amit Kumar [amit.live.sal_at_gmail.com]
Sent: Monday, September 04, 2017 13:25
To: Fluka Discussion list
Subject: [fluka-discuss]: Regarding multiple compton event
Dear All
I have obtained following spectrum using DETECT card in FLUKA for 60 keV gamma falling on 10 micron silicon detector. Here Y-axis is number of events and X-axis is energy deposit in that event in keV.
[Inline image 1]
there was no counts between compton edge (20 keV) and photo peak (60 keV) but experimental results or results obtained using GEANT4 suggest some counts between these to points and I found some where that these points are due to multiple compton events. Following is a similar spectrum obtained using GEANT4
[Inline image 2]
I have doubt whether FLUKA simulates multiple compton events. Please let me whether I am missing any necessary card to account multiple compton events. My input file is attached.
--
Amit Kumar
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Wed Sep 06 2017 - 10:55:25 CEST