Dear Sizwe
the card you need is the LOW-MAT card where you assign to your materials a corresponding cross-section available in FLUKA.
Unfortunately for Thallium and Selenium there is no corresponding cross-section available in FLUKA.
The best approach would be to use the LOW-MAT of a material that exists in FLUKA and has a similar cross-section of interest (for your studies) with the above materials.
I hope this helps
Kind regards
Lefteris
-----------------------
Eleftherios Skordis
Dep. EN/STI, CERN
CH-1211 GENEVA 23
SWITZERLAND
OFFICE: +41-22-7679541<tel:%2B41-22-7675461>
________________________________
From: owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] on behalf of SIZWE SCELO MHLONGO [3698012_at_myuwc.ac.za]
Sent: 23 May 2018 17:02
To: fluka-discuss_at_fluka.org
Subject: [fluka-discuss]: Cross-sections for Uranium, Selenium, and Thallium on FLUKA
Dear FLUKA experts and community,
I have been trying to run a simulation of 14 MeV neutron activation of a sample containing Uranium, Thallium and Selenium but I get the message: "Low energy neutron xsec not found for some media...", the media being the above mentioned elements. Is there a particular card I can use to solve this problem?
Regards,
Sizwe
[
https://www.uwc.ac.za/PublishingImages/UWCDisclaimerBanner.jpg]