Re: "old" heavy ion error

From: Sunil C (csunil11@gmail.com)
Date: Thu Dec 20 2007 - 05:09:01 CET

  • Next message: saull@irs.phy.nrc.ca: "fluka and gfortran"

    Hi
    It is usually because the projectile name is not placed at the first column
    of SDUM. Try starting the name of the projectile exactly at the 71st column
    of the BEAM card.

    Regards
    Sunil

    On 12/17/07, Leif Stawnyczy <leif.stawnyczy@gmail.com> wrote:
    >
    > Dear fluka users,
    >
    > I'm trying to run a simulation and the only output i get (besides the
    > typical .log, .out files) is a .err file that contains the following
    > error:
    >
    > Abort called from FLUKAM reason UNKNOWN PROJECTILE OR "OLD" HEAVY ION
    > OPTION (
    > NO LONGER SUPPORTED) Run stopped!
    > STOP UNKNOWN PROJECTILE OR "OLD" HEAVY ION OPTION (NO LONGER SUPPORTED)
    >
    > Unfortunately, i have no idea what this means. I checked my fluka
    > card line by line, and it seems there's nothing wrong with it. I
    > might have missed something, but i doubt it. Can anybody tell me
    > what's wrong here? I do'nt even know where to look to try and correct
    > this error.
    >
    > Any help is greatly appreciated.
    >
    > Regards;
    >
    > leif
    >
    >


  • Next message: saull@irs.phy.nrc.ca: "fluka and gfortran"

    This archive was generated by hypermail 2.1.6 : Thu Dec 20 2007 - 08:03:29 CET