Re: Use of Deq

From: Sunil C <csunil11@gmail.com>
Date: Mon Mar 31 2008 - 16:57:47 CEST

Hi Stefan

Yes I am using the USRTRACK to score the photons and yes the folding is
being done as within the first few histories I can see the message in the
output file.
USRYILED and PHOTONUC are redundant as I am not using it in this run.

Thanks for posting it here.
The lapse is mine and my apologies to the list memebers for not doing so
myself.

Best Regards
Sunil

On 3/31/08, Stefan Roesler <sroesler@mail.cern.ch> wrote:
>
> Hi Sunil,
>
> I don't have NCRP 144 and IAEA 188; thus can only comment on your input:
>
> - Photonuclear interaction are off by default. Therefore, you'll have to
> uncomment PHOTONUC.
>
> - deq99c.f does not apply to USRYIELD.
>
> - Thus, the only card which folds with dose-equivalent factors in your
> input is USRTRACK. Is this the dose output which you are refering to?
>
> - You are correct, results are in pSv/primary.
>
> - I'd recommend using EMFCUT (both for production and transport
> thresholds) so that you are sure of your cutoffs.
>
> - I guess that you have verified in the output file that deq99c folding
> was indeed applied?
>
>
> I take the liberty to cc fluka-discuss as the discussiuon might also be of
> interest to others (or know a better answer).
>
> Regards
> Stefan
>
>
> On Mon, 31 Mar 2008, Sunil C wrote:
>
> > Hi Stefan
> > I am having a normalization problem in a work of mine.
> > Attached is a typical input where I use a cylindrical detector after a
> certain
> > shield thickness to score photon dose using deq99.f routine.The primary
> beam
> > is electron incident on 10 radiation lengths thickness of several
> targets. I
> > vary the shield thickness and score the dose. On plotting the dose rate
> after
> > shield against the shield thickness, the well known transmission curve
> can be
> > obtained. I get a neat graph except of course at the higher thickness.
> > Extrapolating the graph to zero thickness should give the unshielded
> dose
> > rate. I am comparing this with the NCRP 144 (figure 3.5 page 45) and
> Swanson's
> > IAEA tecdoc 188. I am getting results 100 times lesser unshielded dose
> rate
> > with FLUKA calculations compared to the Swanson's rule of thumb given in
> IAEA
> > 188 (page 53).
> >
> > Am I making a mistake while calculating the dose equivalent?
> > I understand the units are in pSv/primary.
> >
> > Your comments will help me debug the problem.
> >
> > Thanks a lot
> > Best Regards
> > Sunil
> >
>
> --