Hi all,
The cutoff value of electron and photon transport I set in EMFCUT card for graphite is 1keV and 100eV, respectively. But in the output file the vaule is as follows:
1 Correspondence of regions and EMF-FLUKA material numbers and names:
Region EMF FLUKA
1 0 VACUUM 1 BLCKHOLE
Ecut = 0.0000E+00 MeV, Pcut = 0.0000E+00 MeV, BIAS = F, Ray. = F, S(q,Z) = F, Pz(q,Z) = F
2 0 VACUUM 2 VACUUM
Ecut = 0.0000E+00 MeV, Pcut = 0.0000E+00 MeV, BIAS = F, Ray. = F, S(q,Z) = F, Pz(q,Z) = F
3 1 GRAPHITE 26 GRAPHITE
Ecut = 5.1200E-01 MeV, Pcut = 1.0000E-04 MeV, BIAS = F, Ray. = T, S(q,Z) = T, Pz(q,Z) = T
The electron cutoff value is 0.512MeV in the output file which is not the value equals to 1keV that I set in EMFCUT card.
I have no idea what is the reason and I have attached the input and output files in the attachment.
Any help will be appreciated and thank you in advance.
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
- application/x-fluka attachment: test.inp
Received on Tue Nov 26 2019 - 06:50:22 CET