Re: [fluka-discuss]: Issues with HADGT20

From: Paola Sala <paola.sala_at_mi.infn.it>
Date: Mon, 3 Aug 2020 16:43:09 +0200

Dear Phillip
the card looks ok. Would it be possible for you to send the input file?
Otherwise it is difficult to spot the problem (you can send it to me
privately)
Regards
Paola
> Dear FLUKA experts,
>
> As part of a radiation study for an upcoming experiment, I've been trying
> to use the HADGT20 option in some USRBIN cards to measure the fluence in
> some areas of the detector. However, after running over around 200k
> events
> and processing the results with usbsuw and usbrea, I found a fluence of
> zero everywhere in the detector. Here's a sample card:
>
> USRBIN 10. HADGT20M -50. 5. 5.
> 31.775HadD1
> USRBIN -5. -5. 31.695 20. 20. 1. &
>
> In the same simulation, I also used SI1MEVNE and DOSE without running into
> any problems; the format of the cards was exactly the same. Does HADGT20
> need to be treated differently, or is there another problem?
>
> Thank you!
> Phillip Masterson
>


Paola Sala
INFN Milano
tel. Milano +39-0250317374
tel. CERN +41-227679148

__________________________________________________________________________