[fluka-discuss]: How many DETECT cards can use in one input?

From: Yuni <dg1726010_at_smail.nju.edu.cn>
Date: Wed, 26 Aug 2020 08:52:03 +0800

Dear FLUKA experts:


I want simulate a group of CsI detectors, and use DETECT card to score photon events. There are 49 detectors region thus 49 DETECT cards are used in the input. But only 20 DETECT cards feedback output data. That means number of DETECT card is limited in one input? Here is the last detect output data(part):


&nbsp;# Detector n:&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;20&nbsp; &nbsp;CSI19&nbsp; &nbsp; &nbsp;
&nbsp;# N. of energy intervals&nbsp; &nbsp; &nbsp; &nbsp; 1024
&nbsp; 0.000E+00&nbsp; 9.766E-06&nbsp; 1.000E+00&nbsp; 4.472E-01
&nbsp; 9.766E-06&nbsp; 1.953E-05&nbsp; 0.000E+00&nbsp; 1.000E+02
&nbsp; 1.953E-05&nbsp; 2.930E-05&nbsp; 0.000E+00&nbsp; 1.000E+02
&nbsp; 2.930E-05&nbsp; 3.906E-05&nbsp; 0.000E+00&nbsp; 1.000E+02
&nbsp; 3.906E-05&nbsp; 4.883E-05&nbsp; 0.000E+00&nbsp; 1.000E+02
&nbsp; 4.883E-05&nbsp; 5.859E-05&nbsp; 0.000E+00&nbsp; 1.000E+02
&nbsp; 5.859E-05&nbsp; 6.836E-05&nbsp; 0.000E+00&nbsp; 1.000E+02
&nbsp; 6.836E-05&nbsp; 7.812E-05&nbsp; 0.000E+00&nbsp; 1.000E+02
&nbsp; 7.812E-05&nbsp; 8.789E-05&nbsp; 0.000E+00&nbsp; 1.000E+02
&nbsp; 8.789E-05&nbsp; 9.766E-05&nbsp; 0.000E+00&nbsp; 1.000E+02
&nbsp; 9.766E-05&nbsp; 1.074E-04&nbsp; 0.000E+00&nbsp; 1.000E+02
&nbsp; 1.074E-04&nbsp; 1.172E-04&nbsp; 0.000E+00&nbsp; 1.000E+02
..........


Best regards
Yuni

__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Wed Aug 26 2020 - 04:08:04 CEST