try editing MXUSBX parameter in flukapro/\(USRBDX\)
-M
PARAMETER ( MXUSBX = 1100 )
________________________________
From: owner-fluka-discuss_at_mi.infn.it <owner-fluka-discuss_at_mi.infn.it> on behalf of Vojtech Horny <Vojtech.Horny_at_polytechnique.edu>
Sent: Friday, July 30, 2021 7:16 AM
To: fluka-discuss_at_fluka.org <fluka-discuss_at_fluka.org>
Subject: [fluka-discuss]: USRBDX: higher number of detectors
Dear FLUKA developers (and users),
would it be possible to modify some code parameters in such a way that the maximum number of user-defined boundary-crossing detectors (USRBDX) is higher?
The current constraint is 1100 of them, I can imagine using order of magnitude more for my current project.
Best regards,
Vojtěch Horný
Postdoc
LULI : Laboratoire pour l'Utilisation des Lasers Intenses
https://ft.nephy.chalmers.se/~vojtech/index.html
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Sat Jul 31 2021 - 01:09:23 CEST