Dear Stefan,
Unfortunately I do not find any change in the results from bias and
unbiased results. Could you send please your results so I can check it
with myne? Maybe I am doing some mistake when running the input? There
comand to run is the same?
Best regards and thank you for you time, Alessandro Calamida.
Il 25/07/2024 13:04, Stefan E. Mueller ha scritto:
> Dear Alessandro,
>
> also in this case, the uncertainty (look in the _tab.lis-file of your
> scorer 21) should get smaller when the biasing is activated.
>
> At least this is what I get. I also see much more isotopes produced in
> the case which includes biasing.
>
> Cheers,
>
> Stefan
>
> --
> Stefan E. Mueller
> Department of Information Services and Computing - Computational Science
> and Institute of Radiation Physics
> Helmholtz-Zentrum Dresden-Rossendorf
> Tel: +49 (0351) 260 3847
> Stefan.Mueller_at_hzdr.de
> http://www.hzdr.de
>
> Vorstand: Prof. Dr. Sebastian M. Schmidt, Dr. Diana Stiller
> Vereinsregister: VR 1693 beim Amtsgericht Dresden
>
> On Wed, 24 Jul 2024, Alessandro Calamida wrote:
>
>> Dear Stefan,
>>
>> However the RESNUCLEi results are still the same even if split even
>> more the neutrons, why?
>>
>> Best regards and thank you for your time, Alessandro Calamida.
>>
>> Il 24/07/2024 15:38, Stefan E. Mueller ha scritto:
>>> Dear Alessandro,
>>>
>>> your input is working correctly. Running your input and plotting the
>>> USRBIN, there are more events towards the detector, and less away
>>> from the detector, consistent with your biasing scheme.
>>>
>>> The effect of the biasing becomes more visible when plotting the
>>> uncertainties (click "errors" box in the FLAIR plotting section, and
>>> set a linear scale in the colorband cb axis section). The
>>> uncertainty (plotted in percent from 0 to 100% on the color scale)
>>> is much lower in the regions closer to the detector respect to an
>>> unbiased production.
>>>
>>> Cheers,
>>>
>>> Stefan
>>>
>>> --
>>> Stefan E. Mueller
>>> Department of Information Services and Computing - Computational
>>> Science
>>> and Institute of Radiation Physics
>>> Helmholtz-Zentrum Dresden-Rossendorf
>>> Tel: +49 (0351) 260 3847
>>> Stefan.Mueller_at_hzdr.de
>>> http://www.hzdr.de
>>>
>>> Vorstand: Prof. Dr. Sebastian M. Schmidt, Dr. Diana Stiller
>>> Vereinsregister: VR 1693 beim Amtsgericht Dresden
>>>
>>> On Wed, 24 Jul 2024, Alessandro Calamida wrote:
>>>
>>>> Dear FLUKA experts,
>>>>
>>>> I am trying to use the bias options for the first time. However, I am
>>>> not sure if I am using it correctly because I am not seeing any change
>>>> in the usrbin scoring or more statistic in the SiC detector region
>>>> as it
>>>> should be. I attach the input file to this email.
>>>>
>>>> Best regards and thank you for your time, Alessandro Calamida.
>>>>
>>>>
>>>> --
>>>> Questa email è stata esaminata alla ricerca di virus dal software
>>>> antivirus Avast.
>>>> www.avast.com
>>
>> --
>> Questa email è stata esaminata alla ricerca di virus dal software
>> antivirus Avast.
>> www.avast.com
>>
--
Questa email è stata esaminata alla ricerca di virus dal software antivirus Avast.
www.avast.com
__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Thu Jul 25 2024 - 15:57:26 CEST