Re: [fluka-discuss]: Query regarding DOSE

From: Konstantin Batkov <batkov_at_gmail.com>
Date: Mon, 23 Dec 2024 18:19:02 +0100

Dear Ravi,

I might be missing something obvious, but I don’t understand why you would
expect the prompt and induced doses to be identical, even at zero cooling
time. The prompt dose is caused by both radioactive decay and other
reactions, whereas the induced dose comes solely from radioactive
decay-related reactions. Moreover, your "doseZero" is influenced by decays
that occur during the irradiation time, whereas your "dose" is essentially
a Green's function of your source term, meaning it doesn’t account for the
buildup during the irradiation period.

Konstantin


__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Mon Dec 23 2024 - 20:00:07 CET