Re: Data of USRBIN + AUXSCORE identical to just USRBIN

From: Lucia Sarchiapone <Lucia.Sarchiapone_at_lnl.infn.it>
Date: Wed, 14 Jul 2010 09:16:28 +0200 (CEST)

Hello,

your results are identical because the USRBIN with SDUM "ndose", that is
the one you are using to score the dose, is scoring NEUTRON fluence and
the AUXSCORE card does not make any effect on it. You have to score
DOSE-EQ as generalized particle in the USRBIN, and then the AUXSCORE
card properly defined in your input file will produce the result you
want, that is the neutron ambient dose equivalent. The same for photons,
DOSE-EQ in the USRBIN and PHOTON in AUXSCORE.
Cheers,

Lucia

On Jul 13, 2010 10:18 PM, Jason Emory Andrews <jea29_at_uw.edu> wrote:

> Hello FLUKA users and experts,
>
> I am a FLUKA beginner. I want to score neutron and photon equivalent
> doses, but I also just want to score the fluences in order to compare
> to MCNPX data from the same problem. To do this, I use USRBINs for
> the fluences, and additional USRBIN cards outputting to different
> units followed with referencing AUXSCORE cards with SDUM = AMB74. I
> use Flair, so after the run I ask Flair to process and merge the
> cycles.
>
> When I plot the USRBINs, the fluence results are identical to the dose
> results for corresponding particles. Am I using the AUXSCORE cards
> incorrectly? Is Flair using processes which alter either scores
> beyond just data merging? My input is attached. Thanks for your
> time!
>
> Jason Andrews
> University of Washington
Received on Wed Jul 14 2010 - 10:11:47 CEST

This archive was generated by hypermail 2.2.0 : Wed Jul 14 2010 - 10:12:18 CEST