Re: Request for additional files in two-step activation calculation

From: Stefan Roesler <sroesler_at_mail.cern.ch>
Date: Wed, 9 Mar 2011 19:49:56 +0100

Dear Yuanjie,

As Mario wrote, I suggest to wait for next release (a few days?) which
allows to treat cases where you want to set part of the regions to vacuum
in a muuuch more convenient way.

Of course, if you are in a rush or want to modify more in the second step
than just setting regions to vacuum please send an request directly to me
and I will send you all files.

In no case you need deq99c.f anymore, since these conversion coefficients
are available inside FLUKA (card AUXSCORE see manual).

Cheers
Stefan

On Sun, 6 Mar 2011, BI Yuanjie wrote:

> Dear Stefan,
>
> I am Yuanjie Bi, a Ph.D student of Tsinghua University. I am using FLUKA and deq99c.f to calculate the residual dose rate with the vacuum tank of a 100 MeV cyclotron. Now I need to simulate the residual dose rate after some collimators are taken away, so I need to change the geometry for the 2nd step. I read your presentation "Radioactive Isotopes -Production and Decay" and find I can do this using the Two-step method. I am very appreciated if you could send the additional files to me. And also a question: Is the file deq99c.f still needed to convert fluence to dose equivalent in Two-step method?
>
> I am looking forward to your reply.
> Thank you very much!
>
> Best wishes
> Yuanjie
>
>
>
>
Received on Thu Mar 10 2011 - 08:59:46 CET

This archive was generated by hypermail 2.2.0 : Thu Mar 10 2011 - 08:59:54 CET