Dear Denny,
yes use the AUXSCORE card
Some Examples (from the manual):
*...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....
USRBIN 10.0 208.0 -50.0 10.0 10.0 10.0Ene.p
USRBIN -10.0 -10.0 -10.0 100.0 100.0 100.0&
AUXSCORE 2.0 1.0 1.0
* The above AUXSCORE card will filter the energy scoring of the
* USRBIN card to only the energy that is deposited by protons
USRBIN 10.0 ENERGY -50.0 10.0 10.0 10.0Ene.pi
USRBIN -10.0 -10.0 -10.0 100.0 100.0 100.0&
AUXSCORE USRBIN MUONS Ene.pi
* Similar to the previous example but in a name based input
USRBIN 10.0 DOSE-EQ -50.0 10.0 10.0 10.0DoseEq
USRBIN -10.0 -10.0 -10.0 100.0 100.0 100.0&
AUXSCORE USRBIN DoseEq AMB74
* Score ambient dose equivalent in a Cartesian mesh from all particles
USRYIELD 124.0 ALL-PART -87. TARGS3 INAIR 1.0 Fe56
USRYIELD 180.0 0.0 18. 10.0 0.0 3.0 &
AUXSCORE 5.0 -5602600. Fe56 Fe56
* Score yield of 56 Fe ions
cheers
V.
On 03/16/2011 06:27 AM, dengmw_at_student.sysu.edu.cn wrote:
> Dear all,
>
> As you know,dose and deposited energy are produced by at least one kind of
> particle.So is it possible to discriminate the dose and the deposited
> energy produced by different kind of particles?That is to say,can I know
> that how much dose and deposited energy is produced by one particular kind
> of particle,and how much is produced by another kind of particle,if there
> are 2 particles involved.
>
> Yours sincerely,
> Danny
>
>
-- CERN EN/STI-EET Address : CERN, CH-1211 Geneve 23, Switzerland E-mail : vittorio.boccone_at_cern.ch Office : 75821 (from ext. +41 22 767 5821) GSM : 16-5737 (from ext. +41 76 487 5737)Received on Thu Mar 17 2011 - 17:34:21 CET