Hello,
the resnuclei output results are normalized per unit volume if you
provide it, otherwise they are integrated in the whole volume (in this
case the unit Bq/cm3/proton is still meaningful because the default
volume is 1cm3). This is because FLUKA does not calculate automatically
the region volume, and you have to provide it yourself even when you
specify the region.
Regards,
Lucia
On Jul 01, 2011 01:13 PM, mir inamul haq jeri <mirinamulhaq_at_gmail.com>
wrote:
> Hello,
> I want to know if the resnuclei output results are normalized per unit
> volume which we provide as input in RESNUCLE card or the results are
> integrated for the given region and volume.From the manual it seems
> that the
> results should be integrated for the given region but i was pondering
> why we
> need to provide the input volume if we are specifying the region.
> Thank you
>
> --
> MIR INAMUL HAQ JERI
> INSTN SACLAY.
> UNIVERSITY OF PARIS SUD 11.
>
Received on Sat Jul 02 2011 - 23:29:26 CEST
This archive was generated by hypermail 2.2.0 : Sat Jul 02 2011 - 23:29:58 CEST