Re: Units of Resnucle and USRBDX

From: Alberto Fasso' <fasso_at_SLAC.Stanford.EDU>
Date: Sat, 22 Oct 2011 07:51:41 -0700 (PDT)

Hi Mina,

On Fri, 21 Oct 2011, Mina Nozar wrote:

> On 11-10-21 05:01 AM, Vasilis Vlachoudis wrote:
>> describes the units when a decay-run is involved.
>> RESNUCLEi from nuclei/cmc/primary in prompt, becomes Bq/cmc when coupled with DCYSCORE
>
> Did you mean to say "becomes Bq/cmc/s"?

No! Bq is already per second. "Disintegrations per second".

>> USRBDX,... from Part/cmq/prim becomes Part/cmq/s
>> and for the generalized particles energy as written in the Note.3 of the manual gives energy fluence,
>> Regards
>> Vasilis
>
> In general, my understanding is that all 1/primary will become 1/sec in quantities scored using the DCYSCORE card since
> info. on primaries/sec is provided in the IRRPROFI card.
>
> In your case, 5e22 photons/sec
> IRRPROFI 600.0 5E22
>
> So, on page 7 of the Lectures, the unit for DOSE-EQ should be pSv/s, where without a DCYSCORE care, it would be
> pSv/prim. Please correct me if I am wrong.

No, you are right. But that slide is showing the different "generalized
particles". In general, DOSE-EQ is in pSv/prim, and only if connected to an
IRRPROFI command become pSv/s.
On the other hand, ACTIVITY and ACTOMASS can exist only in connection to
IRRPROFI, therefore on page 7 the unit can only be per sec (Bq/cm3, or Bq/g)

Regards,

Alberto