Run loops over a variable in flair

From: George Kharashvili <georgek_at_jlab.org>
Date: Wed, 17 Jul 2013 15:50:28 -0400 (EDT)

Dear FLUKA/flair experts,

It appears that flair-1.1-3 may have a glitch that doesn't allow run loops over a variable that are not integer.
In the attached example I'm trying to scan beam from X=0 to X=5cm in 2mm steps by varying X_POS. Flair creates the correct number of
runs (25), but in each input only the integer part of X_POS is assigned to what 1 in BEAMPOS (first 5 inputs have x=0, second 5 have
x=1, etc.).

I find this tool very useful and would very much appreciate if it worked again.

-George Kharashvili



Received on Wed Jul 17 2013 - 23:43:01 CEST