Fabio,

I checked that you had the right energies in your subroutine (typically an error of units, e.g. GeV instead of MeV could explain some discrepancies) and it seems OK. I am going to assume for now that the angular spectrum is fine although the implementation seems quite cumbersome (by the way, for best practice try to avoid mixing integers with real numbers, specially in ratios). Do dose rate maps look consistent with the emission angle?
I guess the crucial point is the normalization. Which factor did you use to convert pSv/primary into mSv/h/15GBq?

Mario


From: Fabio Pozzi <fabio.pozzi_at_cern.ch<mailto:fabio.pozzi_at_cern.ch>>
Date: Thursday, December 12, 2013 9:35 AM
To: fluka-discuss <fluka-discuss_at_fluka.org<mailto:fluka-discuss_at_fluka.org>>
Subject: [fluka-discuss]: Co-60 source routine

Dear all,

I am simulating a Co-60 source emitting photons within a certain irradiation angle (30 degrees). I wrote a dedicated source routine which sample the emission direction and position according to my needs. This "seems" to work properly. In order to reproduce the two Co-60 photons I make my routine sample the photon energy with equal probability (0.5 each), i.e. once it chooses 1.17 MeV and once 1.33 MeV. I am scoring the dose-rate with USRBIN.
The point is that when I normalize the FLUKA dose rate (which is in pSv/pr) to the source activity (15 GBq in my case) I obtain a dose rate at 1 m from the source around the Sv/h, instead it should be in the mSv/h range (cross-check with Nucleonica).
If you have any idea/hints please let me know (I attached my input file and the source routine).

Thank you in advance.