Re: [fluka-discuss]: scoring optical photons with EVENTBIN

From: Vittorio Boccone <dr.vittorio.boccone_at_ieee.org>
Date: Wed, 3 Sep 2014 23:35:12 +0200

Dear Paolo,
 can you post your input file and optical photons routines?

Best,
Vittorio


On Wed, Sep 3, 2014 at 8:57 AM, maestro <paolo.maestro_at_pi.infn.it> wrote:

> Dear Fluka users
> I am simulating the production of cerenkov photons in two layers of
> squared cells of aerogel.
> In order to make some test, I have set a very large (unphysical)
> absorption coefficient
> for the aerogel, so that all the photons are absorbed in the material
> immediately after production.
> In this way, I can track photons with mgdraw.f and write them on a file
> in the ENDRAW routine.
> However, I wonder if it is possible to score the number of optical photons
> produced in the cells
> by means of the EVENTBIN card. I have tried with
>
> EVENTBIN 8.0 OPTIPHOT -78.0 CH292900 CHLAY01T 1.0 CH.Ed
> EVENTBIN CH000000 CHLAY01T 0.0 1.0 1.0 1000.0 &
>
> where CH.. are the region numbers and CHLAY.. the lattice number.
> Reading the eventbin output, all the cells are filled with zero even the
> ones
> in which (according to mgdraw.f) optical photons have been produced.
> I am not sure about the z upper and lower limits and binning I set.
> I have tried to scan several values but the output is the always the same.
> Can you give some hint about how to proceed?
> Thank you
> Paolo Maestro
>
Received on Thu Sep 04 2014 - 00:47:29 CEST