On 16.06.2015 18:28, 杨博 wrote:
>
> Dear Colleagues,
>
> Recently I used fluka to calulate the attnuation curve of
> bremsstrahlung in Pb ,which is produced by energetic electron hitting
> high-Z target. What I am suprised is the same curves obtained
> for electon energy of 6MeV and 15MeV,even the trend of photon
> attenuation for electron energy of 6MeV is slower than that for
> electron energy of 40MeV . I refer to IAEA188 and find the same
> results as attached. I think for high enegry electorn there are more
> high energy photon and the compton minimum can be regard as the
> attenuation factor, therefore i can't explain the results i
> obtained. If anyone can comment on it, thanks in advance.
>
> Bo Yang
>
>
>
>
Dear Bo Yang,
The linear (or mass) attenuation coefficient is increasing significantly
when photon have energy 10 MeV and more, because of pair production.
For example for lead:
Energy (MeV) / Mass attenuation coefficient (cm^2 / gram).
5,00 0,0426
6,00 0,0436
8,00 0,0459
10,0 0,0489
Best regards,
Mikhail