Re: [fluka-discuss]: RE: Dose-rate

From: NKANYISO ROBERT Mantengu <3477531_at_myuwc.ac.za>
Date: Tue, 14 Jul 2015 10:43:34 +0200

Thank you guys with your solution now its clear and I understand.
THANK YOU!!


Regards
N.R. Mantengu

On Fri, Jul 10, 2015 at 1:23 PM, Joachim Vollaire <joachim.vollaire_at_cern.ch>
wrote:

> Hi
>
>
>
> - For your USRBIN card called “Netro”, you are scoring prompt dose rate
> (you are not associating a cooling time). In that case the results will be
> pSv/primary particle.
>
> To obtain Sv/h you need to normalize the results to your beam intensity in
> protons per second for example (seems to be 1.08e06 protons / sec from your
> irradiation profile definition, which seems quite low ?) and then multiply
> by 3600 (sec -> hour) and divide by 1e12 (pSv -> Sv).
>
>
>
> - For the USRBINs Netro4/5/7/8 the results are pSv/s for the dose rate at
> the specified cooling time (you are using DCYSCORE). To have Sv/h multiply
> by 3600 and divide by 1e12.
>
>
>
> Best of luck with your study
>
> Joachim
>
>
>
>
>
> *From:* NKANYISO ROBERT Mantengu [mailto:3477531_at_myuwc.ac.za]
> *Sent:* 10 July 2015 12:17
> *To:* fluka-discuss_at_fluka.org; Joachim Vollaire
> *Subject:* Dose-rate
>
>
>
> Dear FLUKA users I am lost on how to normalize the results of DOSE-EQ
> obtained from USRBIN card with AUXSCORE card that convert DOSE-EQ to
> ambient dose equivalent. As far as I'm concern the results are in Sv but i
> need them in Sv/hour.
>
> Here I have attached my input file.
>
>
>
> Any comment will be appreciated.
>
> Regards
>
> N.R Mantengu.
>


__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Tue Jul 14 2015 - 12:22:52 CEST

This archive was generated by hypermail 2.3.0 : Tue Jul 14 2015 - 12:23:00 CEST