From: Hamideh Jalali <jalali.hb_at_gmail.com>
Date: Mon, 7 Sep 2015 14:57:12 +0430

Dear Stefan

Thanks for your attention on my question.
Please find attached my input.

Regards
Hamideh

On Mon, Sep 7, 2015 at 1:52 PM, Stefan Roesler <Stefan.Roesler_at_cern.ch>
wrote:

> Dear Hamideh
>
>
>
> Could you please post input and flair file? The question is difficult to
> understand from your below description.
>
>
>
> Cheers
>
> Stefan
>
>
>
> *From:* owner-fluka-discuss_at_mi.infn.it [mailto:
> owner-fluka-discuss_at_mi.infn.it] *On Behalf Of *Hamideh Jalali
> *Sent:* 07 September 2015 06:59
> *To:* fluka-discuss <fluka-discuss_at_fluka.org>
> *Subject:* [fluka-discuss]: USRBIN 1D projection plot
>
>
>
> Dear FLUKA Experts
>
>
>
> In my problem an inclined Si target has been placed in a room (x:-150 to
> 150, y:-50 to 250, z: 0 to 1000 cm) and has symmetry to the lateral walls.
> The beam(produced gas bremsstrahlung) is in z direction with x and y
> coordinate of 0.
>
> I would like to score dose equivalent along the room behind lateral
> walls in near beam height. To have so, I used 1D projection plot of
> USRBIN. I expected to have the same results in both sides of the room but
> the plots are completely different. They are attached.
>
> Please guide me to know where I am wrong.
>
>
>
> Kind Regards
>
> Hamideh
>



__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info

Received on Mon Sep 07 2015 - 13:51:31 CEST